Chapter 4: Desktop Network Interface (DNI) Problems
4-2 Troubleshooting Guide
4.1 After Installing an E22xx Ethernet Card in a Novell Server, Users Cannot
Connect
Check the Startup.ncf file on the Novell Server.
Is the “Set Maximum Physical Receive Packet Size” set to at least 1518?
YN
Set the maximum packet size to 1518.
The frame type (Ethernet-802.2, -802.3, -II, or SNAP) being used on the client and server Personal Computers (PCs) may
not be the same.
Are the frame types different?
YN
Call Cabletron Technical Support.
Set the client and server PCs to use the same type frame and try to connect with the Novell Server.
Can the users connect with the Novell Server?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
4.2 The PC Will Not Boot with an E22xx Card Installed
The Plug-and-Play (PnP) bios may have configured the E22xx card, and now there are configuration conflicts with a
non-PnP legacy card. Change the legacy card configuration settings to avoid conflicts. Boot the PC.
Will the PC boot?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
4.3 The E22xx Card Settings Were Changed Using QuickSet, but When the Driver
Loads, QuickSet Shows Different Card Settings
Quickset changes are only used in non-PnP PCs. The PnP PCs configure the card automatically and ignore changes made
using QuickSet.