Cabletron Systems MT8-MIM Especificaciones Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 114
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
Chapter 9: Token Ring Problems
9-12 Troubleshooting Guide
9.10 TRBMIM Goes into Out-of-Standby Condition
The trouble could be the configuration of other bridges attached to the rings or the associated cabling.
Are there other bridges attached to the rings?
YN
Is there a router connected to either ring?
YN
Check the cable connection from the bridge to the two rings.
Are the cables defective?
YN
Call Cabletron Technical Support.
Replace the defective cables.
Did this action correct the problem?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
Check the ring numbers and the bridge numbers.
Do the TRBMIM ring numbers match those assigned by the other bridges?
YN
Ensure that the station Flexible Network Bus (FNB) ring numbers match the ring numbers assigned by other bridge(s)
and that there are not two rings with the same ring number.
Did this action correct the problem?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
Call Cabletron Technical Support.
Vista de pagina 107

Comentarios a estos manuales

Sin comentarios