Troubleshooting Guide 9-11
9.9 Non-Cabletron Auto-Sensing Interface Card Cannot Insert onto the Cabletron
Systems Active TRMIM, but Operates Properly with a Passive Board
NOTE: The speed fault detection circuit in the Cabletron Systems active modules do not allow a device
to access the ring unless that device is operating at the proper speed. So, if a non-Cabletron auto-sensing
interface card senses the operating speed of the ring and switches accordingly, the Cabletron Systems
port will shut down the port of that auto sensing card if that card attempts to insert at the wrong ring speed.
Are there non-Cabletron auto-sensing interface cards that cannot insert onto the ring?
YN
Is the auto-sensing card set for the proper speed.
YN
Set the auto-sensing card to the proper ring speed.
Can the auto-sensing card insert onto the ring?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
Call Cabletron Technical Support.
Can you adjust the auto-sensing interface card to the proper ring speed?
YN
Call Cabletron Technical Support.
Set the auto-sensing card to the correct speed.
Can the auto-sensing card insert onto the ring?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.