Troubleshooting Guide 9-9
9.7 Communication Between Two Rings Across a Newly Added TRBMIM Is Not
Possible with Internet Packet Exchange (IPX) Protocol
This problem also occurs with 9T122-24 and 9T122-08 devices.
Two rings were operating together properly. But, after a TRBMIM was added between the two rings, communication across
the TRBMIM is now not possible using IPX. The Internet Protocol (IP) is working properly. The TRBMIM is a source route
bridge only.
NOTE: Most IP applications have the routing parameter built into their drivers, unfortunately, IPX ODI
drivers do not. Also, note that Network Driver Interface Specification (NDIS) drivers do have the route field
included in the specification of the drivers.
Is Route.com loaded on the clients (workstations or nodes) in the network?
YN
Load Route.com on the clients.
Is Route.NLM loaded on the client’s servers?
YN
Load Route.NLM on the servers.
Can you communicate between the two rings using the TRBMIM?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.