Troubleshooting Guide 3-9
Therefore, if you are using a multiple interface device like the EMME or EMM-E6, make sure you use the
correct MAC address. An EMME has four MAC addresses. The white label on the front of the EMME shows
the MAC address for the first channel (A). You need to increment the address to the channel that your Network
Manager Station comes in on. If, for example, the data path for the Network Management Station goes through
a TPRMIM set to channel C, then increment the MAC address from CB to CD (for example, from
00:00:10:13:12:CB to 00:00:10:13:12:CD).
Other devices such as the MRXI, IRM-3, TRMM, TRXI, SEHI, MiniMMAC, and MicroMMAC only have one
MAC address assigned, which appears on the white label.
Section 3.2.1 through Section 3.2.3 provide guidelines on how to BootP download to a device using a PC
running SPECTRUM Element Manager, Remote LANVIEW 2.1x and Remote LANVIEW 2.0x applications.
3.2.1 BootP Downloading Using a PC with SPEL
To use SPEL for BootP, proceed as follows:
1. Make sure that you follow the ARP cache or Frequent Destinations instructions described in Section 3.1.1,
step 3, before configuring SPECTRUM Element Manager.
2. Bring up the TFTP/BootP application by either going to the Program group and double clicking on the
TFTP-BootP Services icon, or click once on the icon in the Device list or the map and select the Utilities
TFTP/BootP pulldown menu. The Start Download screen is displayed (Figure 3-7).
Figure 3-7. Start Download Screen