9032563 E1 RS-232 Application
4-7
RS232 Synchronous Views
ClockSrc The source of the port’s bit rate clock. Split means the transmit clock is
internal and the receive clock is external.
Frame Check Errors The total number of frames with an invalid frame check sequence, input
from the port since system re-initialization and while the port state was Up
or Test.
Aborted Frames The number of frames aborted on the port due to receiving an abort sequence
since system re-initialization and while the port state was Up or Test.
Interrupted Frames The total number of frames that failed to be received or transmitted on the
port due to loss of modem signals since system re-initialization and while the
port state was Up or Test.
Xmt. Underrun Errors The total number of frames that failed to be transmitted on the port, since
system re-initialization and while the port state was Up or Test, because
data was not available to the transmitter in time.
Rcv. Overrun Errors The total number of frames that failed to be received on the port, since
system re-initialization and while the port state was Up or Test, because the
receiver did not accept the data in time.
Synchronous Port Detail View
The Synchronous Port Detail View provides configuration information on a selected entry
from the RS232 Synchronous Port Table, and allows you to modify the configuration values.
This view also provides a color-coded pie chart displaying error breakdown statistical
information. A Clock Source button can be toggled between external, internal and split.
To access: Double-click on an entry in the Synchronous Port Table
Error Breakdown Each statistic is presented as a total amount since the device was initialized
and as a percentage of overall traffic. Three buttons at the bottom of the pie
chart select the way in which the data is represented (Total, Delta, and
Accum). Another button, Clear, works in conjunction with the Accum button.
RS232 Synchronous Port Table View (Continued)