LOCAL MANAGEMENT
5-20
Other ways to view OIDs from the SNMP Tools screen, include walking,
stepping, and cycling. Walk and cycle let you review several OIDs at a
time.
Getting and Setting Individual OIDs
To get an OID:
1. Highlight GET, using the arrow keys, and press the Return key (or
press the F6 function key). “<GET> OID (=|F9)” appears.
2. Enter the OID either by:
using the keyboard to enter the OID minus the OID’s prepend
(e.g., if the prepend is 1.3.6.1, and you enter 4.1.3, then the
OID=1.3.6.1.4.1.3).
entering an ‘=’ and the OID suffix (e.g., if you enter =4.1.3, then
the OID=4.1.3). This allows you to digress and not use the
prepend.
pressing F9 to recall an OID already entered. You can then use the
keyboard to modify the recalled OID as necessary.
3. Press the Return key. If there is no instance of that OID, the return
code will specify “MIB_NO_INSTANCE”, otherwise, information
about that OID’s data type, length, and value are displayed.
To get the next OID:
1. Highlight GETNEXT, using the arrow keys, and press the Return
key (or press the F8 function key). “<GETNEXT> OID (=|F9)”
appears.