Cabletron Systems EPIM F3 Guía de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
INSTALLATION REQUIREMENTS/SPECIFICATIONS
2-10
Parameter Typical Worst Worst Case Typical
Value Case Budget Budget
Transmitter Power
50/125 µm
fiber: -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125 µm
fiber: -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140 µm
fiber: -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB
Error Rate: Better than 10
-10
Note: The transmitter power levels and receive sensitivity levels listed
above are Peak Power Levels after optical overshoot. A Peak Power
Meter must be used to correctly compare the values given above to those
measured on any particular port. If Power Levels are being measured with
an Average Power Meter, then 3 dBm must be added to the measurement
to correctly compare those measured values to the values listed above
(i.e. -30.5 dBm peak=-33.5 dBm average).
Ethernet Port - EPIM-F3
Internal
Transceiver: Cabletron Systems FOT-F3™ Fiber Optic Transceiver
Type: ST fiber optic ports.
Note: Transmitter Power decreases as temperatures rise and increases
as temperatures fall. Use the Output Power Coefficient to calculate
increased or decreased power output for your operating environment. For
example, the typical power output at 25° C is -16.4 dBm. For a 4° C
temperature increase, multiply the typical coefficient (-0.15 dBm) by four
and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 81 82

Comentarios a estos manuales

Sin comentarios