TESTING AND TROUBLESHOOTING
4-6
LNK (Green)
When this LED is lit, it indicates an established link between the
associated twisted pair segment and the 10BASE-T device at the other
end of the segment. This LED will remain lit as long as a link is
maintained
If a port receives no data for 16 msec from the device at the other end
of the segment, a positive link test pulse of 100 nsec is sent onto the
transmit link of the twisted pair cable. The MRXI receives these link
test pulses and checks to determine if they occur at the correct rate,
polarity, and pulse shape. If the MRXI receives no link test pulses, or
the pulses are not correct, the transceiver enters the Link Fail State and
the LED will not be lit. The MRXI does not receive or transmit data
until it receives a correct link test pulse or a valid packet.
When the MRXI is powered-on, the LNK LED flashes if the MRXI
detects reversed polarity on the segment attached to the associated
port.
CPU (Flashing Green)
This LED alternates from red to green during power up. After the boot
is complete, the LED flashes green. A flashing green LED indicates
normal operation. A red LED indicates a faulty processor.
4.4 THE LCD DISPLAY
The MRXI is equipped with an LCD display as shown in Figure 4-3. The
LCD display is a diagnostic tool that gives you important status
information about the MRXI such as: Power up diagnostics, Revision
levels, MAC and IP Addresses, and Error Alerts.