SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.5.1
Page 31
Document 0743
Revision 14
June 2002
Command Line Interface (CLI)
Corrected Anomalies
Item Description
1 When executing the show attributes command on a specific model with many list
attributes, the values and IDs of the list attributes now coincide with the values
returned by the show attributes command when a list attribute is specified.
Known Anomalies
Item Description Solution
1 When using the -a switch (create event
alarm), it can take a long time for the
event to appear in the event list. The
command exits successfully, but displays
no output.
The event appears:
-If the model handle was set as current
and no model handle was specified, or
-A landscape was specified and the show
events command is executed on the
user’s model handle.
This issue will be corrected in a future
release of SPECTRUM.
2 It is possible to perform an installation of
the Command Line Interface tools on a
SpectroSERVER-only workstation.
However, the -x switch to show alarms
and show events does not provide the
normal alarm Cause or Event format
information, because the CsPCause and
CsEvFormat files do not exist in the SG-
Support directory. Possible errors
messages are:
no cause information available
(associated with show alarms)
no event format information
available
(associated with show events)
Restore the missing functionality by
copying the SG-Support/CsPCause and
SG-Support/CsEvFormat directories and
files to the $SPECROOT/SG-Support
directory on the SpectroSERVER
workstation.
This issue will be corrected in future
release of SPECTRUM.