Editing a Configuration
Converting Hexadecimal Values to ASCII or Decimal
Creating and Managing Configurations
4-48
Enterprise Configuration Manager
User’s Guide
ECM puts an exact duplicate of the attribute (including a duplicate
instance ID) in the list. (When you perform a Paste operation, the Undo
option in the Edit menu becomes renamed as Undo Paste. Until you
perform some other operation, you can undo this duplication action by
clicking on that Undo Paste option.)
4. Modify the duplicate attribute’s value as necessary ty typing the new
value into the Value field in the lower left corner. ECM does not permit
you to update the configuration until some different value has been
entered; the Update button remains grayed out until you enter the data.
(When you enter data into the field, the Undo option on the Edit menu
becomes renamed as Undo Typing, and you can cancel this input, up
until the time you perform the following update operation, by selecting
that Undo Typing option.)
5. Then click on the Update button to apply your change to the Attribute/
Value list. (When you activate the Update function, whether on the Edit
menu or by clicking on the Update button, the Undo option on the Edit
menu becomes renamed as Undo Update; if you decide to discard this
change, up until the time that you save the modified file, you can click on
that Undo Update option.)
6. Save the configuration by clicking on Save or Save As.
You will receive error prompts if you try to save the configuration before
clicking on the Update button or if you try to close the Configurations
window before updating modifications or saving the configuration.
Figure 4-23. Duplicating an Attribute with Instance IDs
Converting Hexadecimal Values to ASCII or Decimal
In ECM, the values of Octet and Tagged Octet attributes appear in
hexadecimal format. To make editing possible, ECM provides a Convert dialog
box that allows you to format these values in either ASCII or decimal and
then edit them in that format. When you apply these changes to the
configuration and return to the Configurations window, ECM converts the
edited values back to hexadecimal.
Device Attribute Flags Value Flags DeviceInsertable Attributes
RW IfIsAssignedRel
RW IfManagesRel
RW IfOrgRel
RW IfOwnsRel
RW IfProvidesRel
RW If_Instance_ID
RW If_State
RW If_Total_AvgRcvPkts
If_Admin_Status.1 RW 2
If_Admin_Status.2 RW 1
Select
All
Add
Instance ID
Value
2
1
Deselect
All
1
3
2
Update Edit Host ConfigurationCut Paste
Copy
Wild Attr.
Wild Comp.
5