Chapter 3: Installation
3-2 HSIM-W84 Installation Guide
In a shelf installation, the shelf must be able to support 13.6 kg (30 lb) of static weight for each
device on the shelf.
Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at the installation site with
fluctuations of less than 10°C (50°F) per hour.
Maintain a two-inch clearance for each side and the back of the device for adequate ventilation.
Installing an HSIM
You can install an HSIM-W84 in any Cabletron Systems device that supports HSIM technology
(e.g., SmartSwitch 2200, SmartSwitch 6000). Refer to the release notes for the version of firmware
running on the Cabletron Systems device to ensure that the HSIM-W84 is supported. The
following sections provide generic instructions for installing an HSIM-W84 in a SmartSwitch
interface module, or SmartSwitch standalone device. Refer to your specific interface module, or
standalone device documentation for exact HSIM slot and connector locations.
Installing an HSIM in a SmartSwitch 6000 Interface Module
To install an HSIM in a module that supports HSIM technology refer to Figure 3-1 and Figure 3-2
and complete the following steps:
1. Disconnect all network cables from the interface module. Note the ports to which these cables
are attached.
2. Attach the disposable antistatic wrist strap.
3. Unlock the top and bottom plastic locking tabs of the module faceplate.
4. Slide out the interface module and place it on its side with the internal components facing up.
5. Remove and save the two faceplate mounting screws securing the HSIM coverplate and remove
the coverplate. See Figure 3-1.
6. Remove and save the two standoff screws.
!
CAUTION
The HSIM-W84 and the host module or standalone device are sensitive to static
discharges. Use an antistatic wrist strap and observe all static precautions during this
procedure. Failure to do so could result in damage to the HSIM-W84, the host module or
standalone device.