22-5
Messages 500 599
To disconnect the SLIP session, enter the following command. Substitute the session
number for 2.
Local> DISCONNECT SESSION 2
For more information on configuring and managing SLIP ports, refer to the Network
Access Software Management Guide.
Local -561- Starting SLIP or PPP datalink session
Explanation: This message is displayed to the local terminal when the CONNECT
"datalink" command is entered.
Action: No action is required.
Local -562- Invalid SLIP or PPP argument
Explanation: You have attempted to modify a SLIP or PPP characteristic to an incorrect
or out-of-range value.
Action: For more information on the SET/DEFINE/CHANGE SLIP command, refer to
the Network Access Software Commands Reference Guide.
Local -564- Console messages are not output during PPP sessions
Explanation: This message is displayed on the port defined as the access server console
when the PPP enabled command is entered..
Action: No action is required.
Local -565- Max Configures must be between 1 and 15
Explanation: The value for the PORT PPP LCP/IPCP/ATCP/IPXCP MAXCONFIGURE
was out of range.
Action: Configure with a value within the range of 1 and 15.
Local -566- Max Failures must be between 1 and 15
Explanation: The value for the PORT PPP LCP/IPCP/ATCP/IPXCP MAXFAILURE was
out of range.
Action: Configure with a value within the range of 1 and 15.
Local -567- Max Terminate must be between 1 and 15
Explanation: The value for the PORT PPP LCP/IPCP/ATCP/IPXCP MAXTERMINATE
was out of range.
Action: Configure with a value within the range of 1 and 15.