Messages 200 299
19-4
Explanation: The access server is receiving messages that violate the LAT protocol.
Local -215- Connection to service-name not established
Logic error: duplicate queue entry
Explanation: The connection request failed or the existing connection was terminated
because the queue entry id already exists in the queue.
Action: Try to reconnect to the service.
Local -216- Connection to service-name not established
No other users on this virtual circuit
Explanation: The connection request failed or the existing connection was terminated and
the virtual circuit is now inactive.
Action: Try to reconnect to the service.
Local -217- Connection to service-name not established
Insufficient service resources
Explanation: The connection request failed or the existing connection was terminated due
to insufficient memory.
Action: Verify access server memory usage. See the section Verify Access Server Memory
Usage (page 2-6).
Local -218- Connection to service-name not established
Service user disconnect request
Explanation: The connection request failed or the existing connection was terminated
because the host disconnected the session.
Action: Try to reconnect to the service.
Local -219- Connection to service-name not established
Service not available
Step Action
1 Try to reconnect to the service.
2 If the connection fails, reinitialize the access server to downline load the software.
3 Verify that the access server is running the latest software.
4 Try to reconnect to the service.
5 If the error messages reappear, you might have a software problem.