SmartSwitch Router User Reference Manual 105
Chapter 10
RIP Configuration
Guide
RIP Overview
This chapter describes how to configure the Routing Information Protocol (RIP) on the
SmartSwitch Router. RIP is a distance-vector routing protocol for use in small networks.
RIP is described in RFC 1723. A router running RIP broadcasts updates at set intervals.
Each update contains paired values where each pair consists of an IP network address and
an integer distance to that network. RIP uses a hop count metric to measure the distance
to a destination.
The SmartSwitch Router provides support for RIP Version 1 and 2. The SSR implements
plain text and MD5 authentication methods for RIP Version 2.
The protocol independent features that apply to RIP are described in Chapter 8, “IP
Routing Configuration Guide” on page 77.
Configuring RIP
By default, RIP is disabled on the SSR and on each of the attached interfaces. To configure
RIP on the SSR, follow these steps:
1. Start the RIP process by entering the rip start command.
2. Use the rip add interface command to inform RIP about the attached interfaces.