Chapter 26: ospf Commands
SSR Command Line Interface Reference Manual 26 - 23
work both attempt to become the designated
router, the one with the higher priority wins. A
router whose router priority is set to 0 is ineligi-
ble to become designated router. Specify a
number from 0 – 255.
hello-interval
<num>
The length of time, in seconds, between hello
packets that the router sends on this virtual link.
Specify a number from 0 – 255. The default is
60 seconds.
router-dead-interval
<num>
The number of seconds not hearing a router's
Hello packets before the router's neighbors will
declare it down. Specify a number from 0 – 255.
The default value for this parameter is 4 times
the value of the
hello-interval
parameter
poll-interval
<num>
Before adjacency is established with a neigh-
bor, OSPF packets are sent periodically at the
specified poll interval. Specify a number from
0 – 255. The default is 120 seconds.
Restrictions
None.