CHAPTER 2: LOCAL MANAGEMENT
2-10 WPIM-E1 LOCAL MANAGEMENT GUIDE
2.3 FULL E-1 CONFIGURATION USING PPP
This section provides step-by-step instructions for configuring the
WPIM-E1 to use a full E-1 circuit in a PPP environment. This simplified
example assumes the setup shown in figure 2-5 using a MicroMMAC hub
with a BRIM-W6 containing a WPIM-E1 at Site #1. Configurations may
vary depending on the hub.
Figure 2-5. Full E-1 Configuration
The line configuration information shown in Table 2-1 must be supplied
by the service provider.
Table 2-1. Telco Configuration Information
Configuration Information
Required By User
Configuration Information
Supplied By Service Provider
Line Coding HDB3 or AMI
Frame Type E1 or E1-CRC
Clock Source Loop Timing or Local Timing
SITE 1
Telco Cloud
32 Timeslots
(31 customer-usable)
32 Timeslots
(31 customer-usable)
SITE 2