SmartSwitch 90009E106-06Ethernet Switch ModuleUser’s Guide
Introduction1-2 Features Processors The 9E106-06 is equipped with dual advanced Intel i960 ® RISC microprocessors. One processor provides a platform
1-3Introduction The FNB backplane connection is a fixed connection to FNB-1 or FNB-2. This connection allows the 9E106-06 to communicate with other Sm
Introduction1-4 Figure 1-1. The 9E106-06SMB CPU9E106-06ETHERNETFNB
1-5Introduction Related Manuals The manuals listed below should be used to supplement the procedures and technical data contained in this manual.Smar
Introduction1-6
2-1 Chapter 2 Installing the 9E106-06 Module The 9E106-06 Module may be installed in any of the 14 slots available in the SmartSwitch 9000 chassis. T
Installing the 9E106-06 Module2-2 Figure 2-1. Installing the 9E106-06 ModuleMetal Back-PanelModule GuidesModuleJack for ESDWrist StrapPlastic TabEnsu
2-3Installing the 9E106-06 Module Installing EPIMs This section contains procedures on how to add/replace an Ethernet Port Interface Module (EPIM). A
Installing the 9E106-06 Module2-4 Installing the EPIM To install an EPIM:1. Remove the coverplate or the EPIM (whichever applies).2. Slide your new E
2-5Installing the 9E106-06 Module Figure 2-3. Installing an EPIM The Reset Switch The Reset Switch is located on the front panel, under the top plast
Installing the 9E106-06 Module2-6 Figure 2-4. The Reset Switch User-Accessible Components Figure 2-5 shows the various components that are accessible
2-7Installing the 9E106-06 Module Figure 2-5. User-Accessible Components Setting the Module Card DIP Switch An eight-switch DIP switch is located on
Installing the 9E106-06 Module2-8 Figure 2-6. Location of Module DIP Switch12345678i 960BootPROMSMB-1PROM
2-9Installing the 9E106-06 Module See the Cautions at the end of this table. Table 2-2. Function of DIP Switch Switch Function Description8Clear Pa
Installing the 9E106-06 Module2-10
3-1 Chapter 3 Operation The 9E106-06 module is a seven port device, six front panel ports, each representing a separate Ethernet collision domain, an
Operation3-2 System Management Buses There are two management channels within the SmartSwitch 9000 system: the SMB-1 and the SMB-10. These buses prov
3-3OperationDC/DC ConverterThe DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network se
Operation3-4
4-1Chapter 4LANVIEW LEDsThe front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. The 9E106-06 LANV
i Notice Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior
LANVIEW LEDs4-2The functions of the System Management Bus (SMB) and CPU LEDs are listed in Table 4-1.The functions of the FNB Receive LED are listed i
4-3LANVIEW LEDsThe functions of the Ethernet Receive LEDs are listed in Table 4-1.The functions of the Ethernet Transmit LEDs are listed in Table 4-5.
LANVIEW LEDs4-4
5-1Chapter 5SpecificationsTechnical SpecificationsCPU:Dual Intel i960 RISC based microprocessorsMemory:8 Meg. Local DRAM (expandable to 12 Meg.)2 Meg. F
Specifications5-2This equipment meets:The safety requirements of:• UL 1950• CSA C22.2 No. 950 • EN 60950• IEC 950The EMI Requirements of:• FCC Part 15
A-1Appendix AEPIMsThe 9E106-06 Ethernet Switching Module provides one port per channel for Cabletron Systems EPIMs. EPIMs allow connecting to the 9E10
EPIMsA-2EPIM-F1 and EPIM-F2 The EPIM-F1 and EPIM-F2 support Multimode Fiber Optic cabling. Each EPIM has an internal Cabletron Systems FOT-F™ Fiber Op
A-3EPIM-F3EPIM-F3The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equi
EPIMsA-4EPIM-CThe EPIM-C supports thin-net coaxial cabling and is equipped with an internal Cabletron Systems TMS-3™ Transceiver. You can use the TERM
A-5EPIM-A and EPIM-X (AUI Port)The link distance is up to 185 meters on the thin-net coaxial cables.Figure A-4. EPIM-CConnector TypeThis connector typ
ii Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may no
EPIMsA-6Figure A-5. The EPIM-A and EPIM-XTable A-4 lists the DB-15 pinouts. Table A-4. DB-15 PinoutsPin Number Represents Pin Number Represents1 Logic
iii Notice DOC Notice This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio
iv Notice
v Contents Chapter 1 Introduction Features...
Contentsvi Appendix A EPIMs EPIM-T........
1-1 Chapter 1 Introduction The 9E106-06 is a multi-port Ethernet Switch Module for the SmartSwitch 9000 that provides high speed IEEE 802.1D complian